- Home
- Optical Boxes
- Pre-terminated Fiber Access Terminal-FAT
- AT-FAT-6A Fiber Access Terminal
AT-FAT-6A Fiber Access Terminal
Fiber Access Terminal with Pre-terminated/Hardened cable assemblies provides fiber optic cable management for the connection of distribution cables and drop cables with advantages of less cost and faster deployment at the user access point in fiber-optic network.
Pre-terminated/Hardened Fiber Access Terminal helps save installation time and labor cost by plugging the Pre-terminated/Hardened cable assemblies into the matching fiber adapters without terminating fiber optic cable in the field again
Extra Description
ASLA TECH provides Fiber Access Terminal made of high-quality PC and ABS plastic alloy.
AT-FAT-6A Pre-terminated/Hardened Fiber Access Terminal integrates fiber cable fixation, storage, splicing, and distribution in an outdoor and indoor wall mounting and outdoor pole mounting box.
Hardened Patchcord
Drop Cable Structure:
The optical fiber unit is positioned in the center. Two parallel strength members are placed at two sides. Then, the cable is completed with a jacket and Messenger Wire.
Features:
- Water-proof design with IP65 Protection level
- Integrated with splice tray and cable management system
- Fiber bending radius control more than 40mm
- Suitable for the fusion splice or mechanical splice
- 1×4 blockless spitter can be installed as an option
- 6 outlet cable ports for Pre-terminated/Hardened drop cables
- AT-FAT-5B/5B-1 Data Sheet
Item Code Information
Specifications:
Max. Capacity | SC: 6 fibers | |
Max. Inlet Cable Diameter | 14mm | |
Inlet Cable Number | 1 uncut cable port and 2 cable glands | |
Outlet Cable Port | 6 pcs of SC adapters | |
Protection Grade | IP65 | |
Installation Method | Wall mounting and pole mounting (pole ring is optional) | |
Working Environment | Outdoor and indoor | |
Dimension | 170(H)*115(W)*75(D)mm | |
Working Temperature | -20°C~+60°C | |
Storage Temperature | -40°C~+70°C | |
Relative Humidity | 0%~95% | |
Air Pressure | 70~106KPa |
Environmental Characteristics:
Operation Temperature | -20°C~+60°C | |
Storage Temperature | -20°C~+60°C |
Mechanical Characteristics:
Operation Temperature | -20°C~+60°C | |
Storage Temperature | -20°C~+60°C |
Geometrical Characteristics:
Fiber Count | 1 | 1 |
Cable Dimension (mm) | 2.0×5.0 | 5.0 |
Cable Weight (kg/km) | 20 | 50 |
Transmission Characteristics:
Fiber Type | G.652.D | G.657.A1/A2 | G.657.B1/B2 | |||
Wavelength (nm) | 1310 | 1550 | 1310 | 1550 | 1310 | 1550 |
Attenuation (dB/km) | ≤0.45 | ≤0.40 | ≤0.45 | ≤0.35 | ≤0.45 | ≤0.35 |